MIL-C-27072
General Description
This specification covers special purpose electrical multi-conductor and single shielded cable for electronic
circuits where the cable will be protected in racks, tunnels, or within buildings, trailers, or equipment. Cables
constructed using polyvinyl chloride (PVC) on insulated wires or for fillers, tapes, or jackets are not to be used
for aerospace applications.
Part Number Designation
M
|
27072
|
/
|
76
|
F
|
A
|
D
|
A
|
9
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Prefix – denotes an item
covered by the military specification that is defined in the inch-pound system
(U.S.)
|
General specification
number
|
|
Detail Specification
number
|
Basic wire size and stranding
designator
|
Basic wire specification
designator
|
Shield and jacket material
designator
|
Sheath material
designator
|
Sheath color
designator
|
Basic Wire Specification Designator for M27072
Base Wire Designator
|
Specification
|
A
|
MIL-DTL-16878/17
|
B
|
MIL-DTL-16878/18
|
D
|
SAE-AS22759/11, SAE-AS22759/9, or
NEMA-HP3
|
E
|
SAE-AS22759/9 or
NEMA-HP3
|
P
|
MIL-DTL-16878/1
|
Basic Wire size and Stranding Designator for
M27072
Wire and Stranding
Designator
|
Conductor Size AWG
|
Number of Strands
|
Strand Size AWG
|
D
|
12
|
19
|
25
|
F
|
16
|
19
|
29
|
G
|
18
|
19
|
30
|
H
|
18
|
7
|
26
|
J
|
20
|
19
|
32
|
K
|
20
|
7
|
28
|
L
|
22
|
19
|
34
|
M
|
22
|
7
|
30
|
S
|
26
|
7
|
34
|
Sheath Color and Stripe or Band Color Designator for
M27072
Color Designator
|
Sheath Color
|
First Stripe or Band
|
0
|
Black
|
|
1
|
Brown
|
|
2
|
Red
|
|
3
|
Orange
|
|
4
|
Yellow
|
|
5
|
Green
|
|
6
|
Blue
|
|
7
|
Violet
|
|
8
|
Gray
|
|
9
|
White
|
|
A
|
Black
|
Brown
|
B
|
Black
|
Red
|
C
|
Black
|
Orange
|
D
|
Black
|
Yellow
|
E
|
Black
|
Green
|
F
|
Black
|
Blue
|
G
|
Black
|
Violet
|
H
|
Black
|
Gray
|
J
|
Brown
|
Red
|
K
|
Brown
|
Orange
|
L
|
Brown
|
Yellow
|
M
|
Brown
|
Green
|
N
|
Brown
|
Blue
|
P
|
Brown
|
Violet
|
R
|
Brown
|
Gray
|
S
|
Red
|
Orange
|
T
|
Red
|
Yellow
|
U
|
Red
|
Green
|
W
|
Red
|
Blue
|
Y
|
Red
|
Violet
|
X
|
Unstriped
|
|
Z
|
Clear
|
|
Detail Specifications for M27072
Detail Specification
|
Description
|
MIL-DTL-27072/1
|
Cable, Special Purpose, Electrical,
Multiconductor, (3 conductors), M27072/1FAAA*
|
MIL-DTL-27072/7
|
Cable, Special Purpose, Electrical, (2
Conductors) and Single Shielded, M27072/7MDDD*
|
MIL-DTL-27072/9
|
Cable, Special Purpose, Electrical,
Multiconductor (4 conductors) and Single Shielded, M27072/9HBKB*
|
MIL-DTL-27072/16
|
Cable, Special Purpose Electrical,
Multiconductor (3 Conductors), M17072/16DBAA*
|
MIL-DTL-27072/24
|
Cable, Special Purpose Electrical,
Multiconductor (3 Conductors) and Single Shielded, M27072/24FBCA*
|
MIL-DTL-27072/25
|
Cable, Special Purpose Electrical,
Multiconductor (2 Conductors) and Single Shielded, M27072/25JDDA*
|
MIL-DTL-27072/28
|
Cable, Special Purpose Electrical,
Multiconductor (2 Conductors) and Single Shielded, M27072/28KACA*
|
MIL-DTL-27072/29
|
Cable, Special Purpose Electrical,
Multiconductor (12 Conductors) and Single Shielded, M27072/29MACA*
|
MIL-DTL-27072/33
|
Cable, Special Purpose Electrical,
Multiconductor (2 Conductors) and Single Shielded, M27072/33KBCA*
|
MIL-C-27072/37
|
Cable, Special Purpose Electrical,
Shielded; Type I, Style 1, 19 Conductors (No,22 AWG)
|
MIL-DTL-27072/42
|
Cable, Special Purpose Electrical,
Multiconductor (4 Conductors) and Single Shielded, M27072/42JBCA*
|
MIL-DTL-27072/44
|
Cable, Special Purpose Electrical,
Multiconductor (3 Conductors) Single Shielded, M27072/44MAAA*
|
MIL-DTL-27072/48
|
Cable, Special Purpose Electrical,
Multiconductor (3 Conductors) and Single Shielded, M27072/48JDDD*
|
MIL-DTL-27072/61
|
Cable, Special Purpose Electrical,
Multiconductor (3 Conductors) and Single Shielded, M27072/61GEDD*
|
MIL-DTL-27072/65
|
Cable, Special Purpose Electrical,
Multiconductor (10 Conductors) and Single Shielded, M27072/65MACA*
|
MIL-DTL-27072/66
|
Cable, Special Purpose Electrical,
Multiconductor (7Conductors) and Single Shielded, M27072/66LEDD*
|
MIL-DTL-27072/68
|
Cable, Special Purpose Electrical,
Multiconductor (21 Conductors) and Single Shielded, M27072/68KACA*
|
MIL-DTL-27072/70
|
Cable, Special Purpose Electrical,
Shielded; Type I, Style 1, 4 Conductors, M27072/70MACA*
|
MIL-DTL-27072/76
|
Cable, Special Purpose Electrical,
Multiconductor (1 Shielded Pair and 8 Wires Under A Double Shield),
M27072/76SACA*
|
MIL-DTL-27072/79
|
Cable, Special Purpose Electrical,
Multiconductor (7 Conductors), M27072/79KAAA*
|
MIL-DTL-27072/83
|
Cable, Special Purpose Electrical,
Multiconductor (2 Conductors) and Single Shielded, M27072/83MACA*
|
MIL-DTL-27072/88
|
Cable, Special Purpose Electrical,
Multiconductor (2 Conductors) and Single Shield
|
MIL-DTL-27072/89
|
Cable, Special Purpose Electrical,
Multiconductor (3 Conductors) and Single Shielded
|
MIL-DTL-27072/94
|
Cable, Special Purpose Electrical, Single
Conductor, Single Shielded
|
Referenced Standards for M27072
Standard
|
Description
|
FED-STD-228
|
Cable and Wire, Insulated; Methods of
Testing
|
MIL-I-631
|
Insulation, Electrical, Synthetic-Resin
Composition, Non-Rigid
|
MIL-DTL-16878/1
|
Wire, Electrical, Type B, 105
°c , 600 Volts (Insulated, High Temperature)
|
MIL-DTL-16878/17
|
Wire, Electrical, Polyvinyle Chloride (PVC) Insulated, 105°c,
600 Volts, Polyamide Jacket
|
MIL-DTL-16878/18
|
WIRE, Electrical, Polyvinyl Chloride (PVC) Insulated, 105°c,
1000 Volts, Polyamide Jacket
|
MIL-STD-686
|
Cable and Cord, Electrical, Identification
Marking and Color Coding of
|
ASTM-B33
|
Standard Specification for Tinned Soft or
Annealed Copper Wire for Electrical Purposes
|
ASTM-B298
|
Standard Specification for Silver-Coated
Soft or Annealed Copper Wire
|
ASTM-D2116
|
Standard Specification for
FEP-Fluorocarbon Molding and Extrusion Materials
|
ASTM-D3369
|
Standard Specification for
Polytetraflouroethylene (PTFE) Resin Cast Film
|
ASTM-D4066
|
Standard Classification System for Nylon
Injection and Extrusion Materials (PA)
|
ASTM-D4894
|
Standard Specification for
Polytetraflouroethylene (PTFE) Granular Molding and Ram Extrusion Materials (Non-adapted NGS
document)
|
ASTM-4796
|
Standard Specification for Polyethelyne
Plastic Molding and Extrusion Materials
|
NCSL-Z540.1
|
Calibration Laboratories and Measuring and
Test Equipment, General Requirments
|
NEMA-HP3
|
Electrical and Electronic PTFE
(Polytetraflouroethylene) Insulated High temperature Hook-up Wire; Types ET (250 Volts), E (600
Volts), and EE (1000 Volts)
|
SEA-AS22759/9
|
Wire, Electric, Flouropolymer-Insulated,
Extruded TFE, Silver-Coated Copper Conductor, 1000-Volt
|
SEA-AS22759/11
|
Wire, Electric, Flouropolymer-Insulated,
Extruded TFE, Silver-Coated Copper Conductor, 600-Volt
|
|